STATLOCK SWIVEL TRICOT FOLEY 25EA/BX..
SKU
MPSRH-BARFOL0102
In stock
Quick Overview
BARD/DAVOL
Brand | RHS |
---|---|
MPN | BARFOL0102 |
Packaging | BX/25 |
$140.15
Note : Image shown for reference purposes only. Actual product appearance may vary. Please read product description for full and accurate details
Description
Statlock Foley Stabilization Device, manufactured by Bard, are designed to secure foley catheters in place without a leg strap. These are a good alternative to strapping a catheter holder on the leg, because of the unique anchor pad design. The StatLock Latex-free anchor pad is easy to secure to the skin, preventing slipping. Anchor pads are much safer and easier to use than sutures. These anchor pads are air permeable to reduce skin irritation.
The StatLock retainer device attaches to the anchor pads securing the catheter in place. The retainer device holds the catheter using transparent gull wings. To use the StatLock Stabilization Device, simply lift the wings, place the catheter inside, and then close the wings over the catheter.
This process is much safer and simpler than securing with sutures. The Bard StatLock Foley Catheter Stabilization Device can turn on its axis 360 degrees. This is significant, because the extra movement can help to prevent accidental pulling or removal of catheters. The StatLock Catheter Holder fits most silicone or latex foley catheters.
How to Use
- Lay the device on a flat surface, clamp open
- Put the Foley onto the clamp with the Y at the clamp
- Push your fingers under the device
- Using your thumb, close the device
- Press on the clamp arrows along the outer edge of the clamp
- Listen for a click
- Lay the catheter on a leg, with the leg and tube fully extended
- Push the catheter up one inch toward the top of the leg
- Prep the area with alcohol wipes
- Let dry completely
- Wipe on skin protectant
- Let dry completely
- Peel backing off one side
- Lay adhesive down
- Smooth out
- Press the device onto the leg, working away from sticky end
- Remove backing from the second side
- Smooth down, do not stretch
Built for Protection
- Catheters can get crushed
- Clamp swivels, keeping the catheter safe
- Swivel reduces chances of skin shearing
Cleaning Instructions
- Wash with soap and water (or you can use saline or hydrogen peroxide if you want)
- Do not soak
- Do not use alcohol or premoistened wipes for cleaning as this may cause the adhesive to dissolve resulting in early lifting
Removal Instructions
- Use alcohol and a clean cloth or an alcohol wipe
- Rub one edge with alcohol until a corner lifts
- Gently pull up on the corner
- Rub the bottom side of the pad to apply alcohol
- (alcohol dissolves the adhesive)
- *Use an adhesive remover if necessary
Contraindications
- Severe Oedema
- Ascites
- Burns
- Open Wounds
- Sloughing Skin
- Known tape/adhesive allergies
Product Specifications
- Sterile
- 100 Percent Silicone
- Latex Free
- Hpic Code: A4333
- Item Numbers: FOL0100, FOL0101, FOL0102